video
General Surgical Instruments Pfna Femoral Intramedullary Nail

General Surgical Instruments Pfna Femoral Intramedullary Nail

The PFNA Gamma Interlocking Nail System II is a modular proximal femoral fixation platform combining standard and lengthened titanium alloy main nails with blade nail, lag screw, distal locking screw and end-cap options. Standard nails are available in 9.4, 10, 11 and 12 mm diameters with 180, 200 and 240 mm lengths, while lengthened left and right versions cover 300–440 mm in 20 mm increments.

Product Introduction

Titanium Alloy PFNA Gamma Interlocking Nail System II

ORTHOPEDIC TRAUMA FIXATION

Titanium Alloy PFNA Gamma Interlocking Nail System II

A modular PFNA proximal femoral nail system combining standard and lengthened main nails with blade nail, lag screw, 5.0 mm locking screw and end-cap options in a coordinated titanium alloy fixation platform.

Standard & Lengthened Ø 9.4 / 10 / 11 / 12 mm 180–440 mm Titanium Alloy
PFNA Gamma Interlocking Nail System II assembled implant
Product Overview

Expanded PFNA Configuration for Proximal Femoral Fixation

The PFNA Gamma Interlocking Nail II platform expands the PFNA configuration by combining a titanium alloy main nail with multiple proximal fixation options. The standard main nail is available in 9.4, 10, 11 and 12 mm diameters with 180, 200 and 240 mm lengths, while the lengthened left and right versions cover 300–440 mm in 20 mm increments.

Depending on the selected configuration, this titanium PFNA intramedullary nail system can be combined with an 11 mm blade nail, 7 mm or 11 mm lag screw, 5.0 mm distal locking screw, standard end cap and locking end cap. This gives the platform a broader component-selection range than a single fixed PFNA construct.

Key Design Advantages

01

5° Proximal Valgus Angle

The source material describes a 5° valgus angle at the proximal main nail, intended to support a minimally invasive approach to the apex of the greater trochanter.

02

Combined Interlocking Concept

The proximal combined interlocking structure is presented as supporting stability, anti-rotation control and compression during pressure-screw tightening.

03

Trapezoidal Proximal Section

The catalog highlights a trapezoidal proximal main-nail section intended to enhance proximal stability and facilitate early weight-bearing according to the product design description.

04

Distal Stress-Relief Design

A bifurcated distal profile is described as reducing stress concentration at the distal end of the implant.

Product Details

PFNA Gamma Interlocking Nail II proximal design

Proximal Fixation Architecture

The proximal portion integrates the main nail with the selected blade or lag-screw fixation component.

lengthened PFNA proximal femoral nail

Lengthened Main Nail

Left and right lengthened versions are listed from 300 to 440 mm, with 20 mm between specifications.

PFNA blade nail

PFNA Blade Nail

The PFNA blade nail is specified as Ø11 × 70–120 mm, with 5 mm increments.

PFNA lag screw fixation component

PFNA Lag Screw

The PFNA lag screw fixation system includes Ø7 × 65–115 mm and Ø11 × 70–120 mm options, each in 5 mm increments.

5.0 mm PFNA distal locking screw

Distal Locking Screw

The distal locking screw is listed at 5.0 mm diameter with 30–50 mm lengths in 5 mm increments.

Technical Specifications

Component Diameter / Specification Length Type Material
PFNA Main Nail II 9.4 / 10 / 11 / 12 mm 180 / 200 / 240 mm Standard Titanium Alloy
PFNA Main Nail II 9.4 / 10 / 11 / 12 mm 300–440 mm; 20 mm increments Lengthened Left / Right Titanium Alloy
Locking Screw Ø5.0 mm 30–50 mm; 5 mm increments Distal Locking Titanium Alloy
Blade Nail Ø11 mm 70–120 mm; 5 mm increments Proximal Fixation Titanium Alloy
Lag Screw Ø7 mm 65–115 mm; 5 mm increments Proximal Fixation Titanium Alloy
Lag Screw Ø11 mm 70–120 mm; 5 mm increments Proximal Fixation Titanium Alloy
End Cap Standard - Accessory Titanium Alloy
Locking End Cap Standard - Accessory Titanium Alloy
Design & Configuration

A Broader PFNA Component Platform

The system is built around a standard or lengthened PFNA main nail and can be configured with blade-nail or lag-screw proximal fixation components. Distal locking is supported by a 5.0 mm screw, while the catalog also lists standard and locking end-cap options.

Final indications, implant selection, surgical technique and weight-bearing decisions must follow the product label, IFU, surgeon assessment and local regulatory requirements.

Frequently Asked Questions

1. What is different about PFNA Gamma Interlocking Nail System II?

The system provides standard and lengthened main-nail options together with multiple proximal fixation choices, including a blade nail and two lag-screw specifications.

2. What standard main-nail sizes are available?

Standard diameters are 9.4, 10, 11 and 12 mm. Listed lengths are 180, 200 and 240 mm.

3. What lengthened nail sizes are available?

The lengthened left and right types are available from 300 to 440 mm in 20 mm increments.

4. What PFNA blade nail specification is listed?

The blade nail is Ø11 mm with lengths from 70 to 120 mm in 5 mm increments.

5. What lag screw options are available?

Two lag-screw families are listed: Ø7 × 65–115 mm and Ø11 × 70–120 mm, both in 5 mm increments.

6. What is the distal locking screw size?

The distal locking screw is Ø5.0 mm with 30–50 mm lengths in 5 mm increments.

7. What material is specified?

The provided catalog lists the main nail, blade nail, lag screws, locking screw and end caps as titanium alloy.

Request PFNA System Specifications

Please provide the required main-nail type, diameter, length, proximal fixation component, locking screw length, destination market and estimated order quantity.

Hot Tags: general surgical instruments pfna femoral intramedullary nail, China general surgical instruments pfna femoral intramedullary nail manufacturers, suppliers, factory, intramedullary nails

Send Inquiry

whatsapp

Phone

E-mail

Inquiry