video
Multi-Configuration ENT Plasma Electrode Series

Multi-Configuration ENT Plasma Electrode Series

This ENT plasma electrode series is designed for a variety of minimally invasive otolaryngology procedures. The platform can be configured with spherical, grid-shaped, 35° round, single-filament, circular-tubular and U-shaped working tips, allowing different models to be selected according to the anatomical site and treatment requirement.When used with a compatible plasma RF generator, the series is suitable for procedures involving the nasal turbinates, tonsils, adenoids and vocal cords, supporting localized tissue ablation and hemostasis according to the selected model and operating mode.

Product Introduction

ENT Plasma Electrode Platform

ENT Plasma Electrode Series for Nasal, Tonsil, Adenoid & Laryngeal Procedures

A multi-configuration ENT RF electrode family for nasal, tonsil, adenoid and laryngeal procedures, with seven working-tip geometries, selectable diameters, working lengths, irrigation arrangements and generator connector options.

ENT plasma electrode and ENT RF electrode series for nasal tonsil adenoid and laryngeal procedures

ENT Plasma Electrode Product Overview

This ENT plasma electrode family provides distinct electrode geometries rather than a single universal tip. Spherical, grid, angled round, filament, tubular and U-shaped profiles support model selection according to the intended access route and tissue-contact pattern. Working diameters range from 2.0 mm to 6.0 mm, while available working lengths extend from 110 mm to 260 mm. Selected long-shaft models include a bendable distal section, and most configurations incorporate a waterway. Buyers searching for an ENT coblation wand should confirm the required procedure, tip geometry, connector and generator compatibility, because this page specifies the products as plasma RF electrodes.

Tip-Specific Selection

Choose the working profile by anatomical site, access route and desired contact pattern.

Directional Reach

Bendable 260 mm options support directional positioning along deeper, curved pathways.

Waterway Options

Irrigated configurations provide fluid delivery; the arrangement is selected by model.

Connector Matching

Multiple connector formats are available for matching with compatible plasma RF systems.

ENT RF Electrode Application Coverage

Nasal Turbinate   |   Tonsil   |   Adenoid   |   Laryngeal Procedures

For procurement searches such as tonsil coblation wand, adenoid coblation wand, turbinate coblation wand or laryngeal plasma electrode, select the model by the listed application, tip geometry, shaft dimensions, waterway and verified generator interface. Final use must follow the applicable product labeling, instructions and local registration requirements.

ENT plasma electrode product detail ENT plasma electrode configuration detail ENT plasma electrode working tip detail

Seven ENT Plasma Electrode Configurations

Select by working-tip geometry, shaft diameter, reach and waterway. These are defined electrode models; the tips are not universal detachable accessories.

DJZ0115-02 ENT plasma electrode working tip

DJZ0115-02

Tip: Spherical tip   |   Diameter: 2.0 mm   |   Length: 115 mm

Waterway: No   |   Suggested application: Nasal turbinate procedures

DJZ1170-01 ENT plasma electrode working tip

DJZ1170-01

Tip: Grid tip, customizable   |   Diameter: 4.2 / 6.0 mm   |   Length: 150 mm

Waterway: Yes   |   Suggested application: Tonsil and adenoid procedures

DJZ1260-01 ENT plasma electrode working tip

DJZ1260-01

Tip: 35-degree round tip   |   Diameter: 4.0 mm   |   Length: 150 mm

Waterway: Yes   |   Suggested application: Tonsil and adenoid procedures

DJZ1260-02 ENT plasma electrode working tip

DJZ1260-02

Tip: Single-filament, bendable   |   Diameter: 2.8 mm   |   Length: 260 mm

Waterway: Yes   |   Suggested application: Delicate laryngeal procedures

DJZ1260-03 ENT plasma electrode working tip

DJZ1260-03

Tip: Circular tubular, bendable   |   Diameter: 4.2 mm   |   Length: 260 mm

Waterway: Yes   |   Suggested application: Delicate laryngeal procedures

DJZ1120-01 ENT plasma electrode working tip

DJZ1120-01

Tip: U-shaped, bendable   |   Diameter: 6.0 mm   |   Length: 120 mm

Waterway: Yes   |   Suggested application: Tonsil and adenoid procedures

DJZ1110-01 ENT plasma electrode working tip

DJZ1110-01

Tip: U-shaped, bendable   |   Diameter: 4.2 mm   |   Length: 110 mm

Waterway: Yes   |   Suggested application: Tonsil and adenoid procedures

ENT RF Electrode Connector Options

Connector configurations may cover Smith & Nephew, Stryker, Johnson & Johnson, Bonss, MECHAN, Forerunner, GAOTON and other compatible systems. Brand names are used only to identify potential compatibility.

Before ordering, please send the generator brand and model, a clear photo of the generator socket, and photos of the original connector body and terminal face. Final compatibility must be confirmed before production.
Each card pairs the connector body with its terminal-face detail whenever both reference views are available.
5-pin / GAOTON type connector body

01   5-pin / GAOTON type

Connector appearance and terminal detail shown for ordering reference.

Forerunner-compatible type connector body

02   Forerunner-compatible type

Connector appearance and terminal detail shown for ordering reference.

6-pin / Korea-market type connector body

03   6-pin / Korea-market type

Connector appearance and terminal detail shown for ordering reference.

6-pin interface type connector body

04   6-pin interface type

Connector appearance and terminal detail shown for ordering reference.

8-pin / Smith & Nephew Quantum 2 type connector body

05   8-pin / Smith & Nephew Quantum 2 type

Connector appearance and terminal detail shown for ordering reference.

8-pin / Smith & Nephew Quantum 2 variant connector body

06   8-pin / Smith & Nephew Quantum 2 variant

Connector appearance and terminal detail shown for ordering reference.

13-pin button type / Smith & Nephew Quantum 2 connector body

07   13-pin button type / Smith & Nephew Quantum 2

Connector appearance and terminal detail shown for ordering reference.

14-pin interface type connector body

08   14-pin interface type

Connector appearance and terminal detail shown for ordering reference.

27-pin / Smith & Nephew Quantum 2 type connector body

09   27-pin / Smith & Nephew Quantum 2 type

Connector appearance and terminal detail shown for ordering reference.

Johnson & Johnson type connector body

10   Johnson & Johnson type

Connector appearance and terminal detail shown for ordering reference.

Banana connector 4.0L connector body

11   Banana connector 4.0L

Connector appearance and terminal detail shown for ordering reference.

Banana connector 4.0 connector body

12   Banana connector 4.0

Connector appearance and terminal detail shown for ordering reference.

Banana connector 2.5 connector body

13   Banana connector 2.5

Connector appearance and terminal detail shown for ordering reference.

High-frequency connector connector body

14   High-frequency connector

Connector appearance and terminal detail shown for ordering reference.

Bonss ENT type connector body

15   Bonss ENT type

Connector appearance and terminal detail shown for ordering reference.

Bonss orthopedic-system type connector body

16   Bonss orthopedic-system type

Connector appearance and terminal detail shown for ordering reference.

MECHAN ENT type connector body

17   MECHAN ENT type

Connector appearance and terminal detail shown for ordering reference.

Coblator 8-pin type connector body

18   Coblator 8-pin type

Connector appearance and terminal detail shown for ordering reference.

Stryker type connector body

19   Stryker type

Connector appearance and terminal detail shown for ordering reference.

8-pin / Smith & Nephew Quantum 2 type connector body

20   8-pin / Smith & Nephew Quantum 2 type

Connector appearance and terminal detail shown for ordering reference.

ENT Plasma Electrode Frequently Asked Questions

How should an ENT plasma electrode model be selected?

Start with the procedure site, then confirm the preferred tip geometry, access length, shaft diameter, waterway and connector. For quotations, provide these details together with the generator information.

Which configurations include a bendable section?

The single-filament, circular-tubular and U-shaped models listed as bendable include a shape-adjustable distal section. Bending must remain within the product instructions.

Are the seven working tips interchangeable?

No. Each item is supplied as a defined electrode configuration. Select the required head shape and specifications before ordering.

Is this ENT plasma electrode the same as an ENT coblation wand?

This page identifies the products as plasma RF electrodes. ENT coblation wand is a common procurement search term, but the required model should be confirmed from the procedure, electrode geometry, generator interface and applicable product labeling rather than search terminology alone.

What information is needed to confirm the connector?

Please send the RF generator brand and model, socket photo, original connector photos and required electrode model. Matching is confirmed from the complete set of information rather than the brand name alone.

Need help selecting an ENT plasma electrode and connector?

For distributors comparing an ENT plasma electrode manufacturer, send the procedure, required electrode model or specifications, generator model and connector photos to zhanghao@cnjxxd.com.

Hot Tags: multi-configuration ent plasma electrode series, China multi-configuration ent plasma electrode series manufacturers, suppliers, factory, Humeral Nail Kit

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag