Pen Type RF Probe & Arthroscopy Plasma Electrode
Slim Arthroscopic RF Probe with Directional Tip Control:
This pen style plasma electrode uses a narrow, button-free body that supports a familiar pencil grip and leaves the fingers free to roll the shaft. The platform is intended for positioning interchangeable plasma tips through confined arthroscopic approaches, with working-end options selected according to the intended joint, access path and tissue-contact pattern.

Pen Style Plasma Electrode for Rotational Arthroscopic Control
Unlike a control-button handle, this version places no switches beneath the fingers. Its uninterrupted cylindrical grip is built around mechanical guidance: advance the shaft, rotate it between the fingers and align the selected distal geometry with the target area. Energy delivery is handled through the compatible generator and foot control.
Uninterrupted Grip Surface:
A clean cylindrical body allows finger placement to change naturally without working around raised control keys.
Fine Rotational Adjustment:
Rolling the handpiece changes distal-tip orientation while the hand remains close to the instrument axis.
Geometry Chosen at the Tip:
Hooked, rounded, sloped, ring and planar ends provide distinct contact profiles for different arthroscopic tasks.
Foot-Controlled Activation:
Separating activation from the handpiece keeps the grip simple; the exact operating logic follows the selected RF generator
Match the Arthroscopy Ablation Electrode Contact Profile to the Access Path
Eleven distal configurations are available on this pen type RF probe platform. Compare approach angle, active-end geometry and fluid-path design before specifying a catalog code. Buyers using arthroscopy ablation electrode or joint plasma probe as procurement search terms should still select the actual catalog configuration from the listed tip geometry, irrigation requirement and verified generator connector.
![]() |
DJZ0140-02
30 to 50 deg. Single HookFluid path: Without irrigation | Selection focus: Arthroscopic hook electrode geometry for meniscal or ligament work |
![]() |
DJZ0140-03
0 deg. Single HookFluid path: Without irrigation | Selection focus: Hook geometry suitable for buyers comparing a meniscus RF probe for meniscal or ligament work |
![]() |
DJZ1140-01
90 deg. Round TipFluid path: Integrated irrigation | Selection focus: Contact geometry for synovial or cartilage work |
![]() |
DJZ1140-02
90 deg. Multi-Electrode Round TipFluid path: Integrated irrigation | Selection focus: Contact geometry for synovial or cartilage work |
![]() |
DJZ1140-03
35 deg. Round TipFluid path: Integrated irrigation | Selection focus: Contact geometry for synovial or cartilage work |
![]() |
DJZ1140-03-01
Y-Shaped TipFluid path: Integrated irrigation | Selection focus: Contact geometry for synovial or cartilage work |
![]() |
DJZ1140-04
Special-Shaped TipFluid path: Integrated irrigation | Selection focus: Contoured access for ligament or retinacular release |
![]() |
DJZ1140-08
Blade-Shaped TipFluid path: Integrated irrigation | Selection focus: Distal geometry intended for hip-joint access |
![]() |
DJZ1140-09
Ring-Shaped TipFluid path: Integrated irrigation | Selection focus: Distal geometry intended for hip-joint access |
![]() |
DJZ1140-10
Sloped Multi-Electrode TipFluid path: Integrated irrigation | Selection focus: Multi-point contact for fibrous tissue or ligament work |
![]() |
DJZ1140-11
Planar Multi-Electrode TipFluid path: Integrated irrigation | Selection focus: Multi-point contact for fibrous tissue or ligament work |
Ordering sequence: identify the portal trajectory first, then choose distal geometry, irrigation requirement and generator connector. Final suitability remains subject to the intended procedure and local clinical judgment.
|
WHERE PEN-GRIP HANDLING FITS
Joint Plasma Probe Options for Procedures That Benefit from Shaft RotationThis slim arthroscopic RF probe format can be considered for knee, shoulder and hip arthroscopy when the operator needs to redirect an angled working end through a restricted approach. Procedure contexts: meniscal work, ligament-related procedures, synovial treatment, cartilage work, retinacular release and fibrous-tissue resection. |
MATCH THE CABLE END
Connector Choice Is Part of the OrderThe same pen-format instrument can be supplied with several cable-end structures. Pin count, plug diameter and connector body must agree with the receiving generator. Use the photographs below as a visual shortlist, then provide the equipment label and socket view for verification. |
Compare Body Shape, Pin Layout and Plug Size
Each card pairs the complete connector body with a face-on interface view where available. This makes it easier to narrow the options before our team checks the generator nameplate and port.
5-Pin InterfaceVisual reference for a GAOTON-style five-pin cable end. |
Forerunner InterfaceForerunner-style housing shown with its keyed face. |
||||
6-Pin Interface - KoreaKorean-market six-contact layout; verify the key position. |
6-Pin InterfaceA second six-contact body form for visual comparison. |
||||
8-Pin Interface - Quantum 2Quantum 2-style multi-pin reference; confirm generator generation. |
8-Pin Interface - Alternative BodyDifferent Quantum 2-style housing with a distinct cable exit. |
||||
13-Pin Button-Type InterfaceThirteen-contact button-type body shown from side and face. |
14-Pin InterfaceFourteen-contact plug body; socket photo required for matching. |
||||
27-Pin Interface - Quantum 2Quantum 2-style multi-pin reference; confirm generator generation. |
Johnson & Johnson InterfaceJohnson & Johnson-style housing and interface reference. |
||||
4.0L Banana PlugExtended 4.0 mm banana-plug format. |
4.0 Banana PlugStandard-length 4.0 mm banana-plug format. |
||||
2.5 Banana PlugCompact 2.5 mm banana-plug format. |
High-Frequency ConnectorHigh-frequency cable termination without a multi-pin housing. |
||||
Bonss ENT InterfaceBonss ENT-style body; application label does not replace port verification. |
Bonss Orthopedic InterfaceBonss orthopedic-style housing with face detail. |
||||
MECHAN ENT InterfaceMECHAN ENT-style connector body and keyed interface. |
Coblator 8-Pin InterfaceCoblator-style eight-contact format shown for comparison. |
||||
Stryker InterfaceStryker-style cable end with its mating face. |
8-Pin Interface - Quantum 2Additional Quantum 2-style body variant; compare both housing and pin face. |
Do not order from pin count alone. Housing keys, electrical definition and generator version can differ even when two plugs look similar. Send one photo of the equipment nameplate and one straight-on photo of the socket for a final match check.
Pen Type RF Probe Questions About Handling and Selection
How is this version different from a hand-controlled electrode?
Its handle has no integrated control keys. The design prioritizes a smooth pen grip and rotational guidance, while activation is assigned to the compatible system and foot control.
When should an angled tip be considered?
An angled or hooked end may assist when the target cannot be approached face-on. Selection should reflect portal position, target anatomy and the surgeon's preferred working direction.
Which configurations can be considered when sourcing a meniscus RF probe?
The listed DJZ0140-02 and DJZ0140-03 use single-hook working ends and are described for meniscal or ligament work. Final model selection should follow portal trajectory, target anatomy, generator compatibility and the applicable product labeling.
Which catalog options have no integrated irrigation path?
DJZ0140-02 and DJZ0140-03 are listed without irrigation. The DJZ1140 configurations shown on this page are listed with an integrated fluid path.
What photographs help prevent a connector mismatch?
Provide the generator's front panel, a close face-on view of the electrode socket and the equipment nameplate. Include the generator model in the inquiry text.
Build the Correct Pen Type RF Probe Configuration
For distributors comparing an arthroscopic electrode manufacturer, send the procedure category, required working-end geometry, irrigation preference, generator identity, port photographs and delivery country for configuration review and quotation.
Email: zhanghao@cnjxxd.com | WhatsApp: +86 158 8119 9040
Hot Tags: slim pen-type plasma electrode for arthroscopy, China slim pen-type plasma electrode for arthroscopy manufacturers, suppliers, factory, Bone Rongeur, Cryo Storage Boxes, Dental Chair Unit, Foam Dressing, Medical Equipment, Sample Containers