video
High Quality Interlocking Intramedullary Nail

High Quality Interlocking Intramedullary Nail

The Titanium Femoral Interlocking Intramedullary Nail System is a modular left- and right-sided femoral fixation platform with 9–12 mm main-nail diameters and 340–420 mm lengths. The system includes 5.0 mm locking screws, 6.5 mm solid and cannulated lag screws, and 0 / 5 / 10 / 15 mm end-cap options, with the supplied catalog identifying the listed components as titanium alloy.

Product Introduction

Titanium Femoral Interlocking Intramedullary Nail System – Left & Right Types

ORTHOPEDIC TRAUMA FIXATION

Titanium Femoral Interlocking Intramedullary Nail System – Left & Right Types

A modular left right femoral interlocking nail platform combining long titanium main nails with solid or cannulated lag screws, distal locking screws and multiple end-cap options.

Ø 9 / 10 / 11 / 12 mm 340–420 mm Left & Right Types Titanium Alloy
product-627-627
Product Overview

Long Femoral Intramedullary Fixation Platform

This long femoral intramedullary nail system is built around left- and right-specific main nails with diameters of 9, 10, 11 and 12 mm. The listed length range is 340–420 mm, with one specification every 20 mm. The extended main-nail configuration provides the core structure for the femoral interlocking platform.

The system can be combined with 5.0 mm locking screws, 6.5 mm solid or cannulated lag screws and end caps in 0, 5, 10 and 15 mm specifications. The supplied application diagrams also illustrate reconstruction, femoral and gamma-style configurations, allowing the page to present the product as a versatile reconstruction femoral nail system rather than a single fixed construct.

Key Advantages

01

Left & Right Main Nail Options

Dedicated left- and right-sided main-nail versions are listed for the femoral interlocking system.

02

340–420 mm Long Nail Range

The main nail is listed from 340 to 420 mm in 20 mm increments, with 9–12 mm diameter selections.

03

Two Lag Screw Configurations

Both a solid lag screw femoral nail configuration and a cannulated lag screw femoral nail configuration are supported by 6.5 mm lag-screw options.

04

Multiple End-Cap Lengths

End caps are listed in 0, 5, 10 and 15 mm specifications for additional assembly selection.

Product Details

product-672-658

Assembled Femoral Nail

Product view showing the long main nail with proximal and distal fixation components.

product-552-591

Left / Right Main Nail

Long titanium main nail with multiple proximal and distal locking openings.

product-623-576

Lag Screw

Both solid and cannulated lag screws are listed at Ø6.5 mm with 65–115 mm lengths in 5 mm increments.

product-617-572

Locking Screw

The locking screw is listed at Ø5.0 mm with lengths from 30 to 80 mm in 5 mm increments.

product-559-558

End Cap

End-cap specifications are listed as 0, 5, 10 and 15 mm.

Technical Specifications

Component Diameter Length / Specification Material
Femoral Interlocking Nail (L/R) 9 / 10 / 11 / 12 mm 340–420 mm; every 20 mm Titanium Alloy
Locking Screw 5.0 mm 30–80 mm; every 5 mm Titanium Alloy
Lag Screw (Solid) 6.5 mm 65–115 mm; every 5 mm Titanium Alloy
Lag Screw (Cannulated) 6.5 mm 65–115 mm; every 5 mm Titanium Alloy
End Cap - 0 / 5 / 10 / 15 mm Titanium Alloy
Configuration Illustration

Multiple Femoral Fixation Configurations

The supplied illustration shows three configurations of the femoral intramedullary platform, including reconstruction, femoral and gamma-style arrangements. This visual is kept free of text so the surrounding HTML content can be translated automatically for multilingual pages.

Final indications, fixation configuration, implant selection and surgical use must follow the product label, IFU, surgeon assessment and local registration requirements.

product-400-393

Frequently Asked Questions

1. Are left and right main nails available?

Yes. The catalog specifically lists left and right types.

2. What main-nail diameters are available?

9, 10, 11 and 12 mm.

3. What main-nail lengths are available?

340–420 mm, with one specification every 20 mm.

4. What lag-screw options are listed?

Both solid and cannulated lag screws are listed at 6.5 mm diameter and 65–115 mm lengths.

5. What locking screw sizes are available?

Ø5.0 mm with lengths from 30 to 80 mm in 5 mm increments.

6. What end-cap specifications are available?

0, 5, 10 and 15 mm.

7. What material is specified?

The supplied catalog identifies the main nail, screws and end cap as titanium alloy.

Request Femoral Nail Specifications

Please provide the required left/right type, main-nail diameter and length, lag-screw configuration, locking screw length, destination market and estimated order quantity.

Email Inquiry WhatsApp Inquiry

Hot Tags: high quality interlocking intramedullary nail, China high quality interlocking intramedullary nail manufacturers, suppliers, factory, Femoral Tuberosity Intramedullary Nail, , intramedullary nails

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag